1 00:00:00,080 --> 00:00:03,880 The cooler temps are here and it's time to get ready. In staying 2 00:00:03,880 --> 00:00:06,600 on the road today, we're going to talk about furnace problems. Should 3 00:00:06,600 --> 00:00:11,000 you maintain, repair, or replace your RV furnace? And in quick 4 00:00:11,000 --> 00:00:14,880 tips, should you replace your RV furnace with a Fogotti furnace? 5 00:00:15,520 --> 00:00:21,440 And in smart tips, familiarize yourself with your tools. I'm Eric 6 00:00:21,440 --> 00:00:25,360 Stark. Welcome to the Smart rver podcast. If you'd rather be 7 00:00:25,360 --> 00:00:29,440 camping than sitting in a repair shop, you're in the right 8 00:00:29,440 --> 00:00:33,700 place. In every episode, I'll walk you through the practical DIY 9 00:00:33,700 --> 00:00:38,060 maintenance and repairs that keep you on the road. Welcome back, 10 00:00:38,060 --> 00:00:43,060 Smart RVers. Today is episode 212, and let's just jump into it 11 00:00:43,060 --> 00:00:46,940 today. All right, let's talk about wholesale warranties for a 12 00:00:46,940 --> 00:00:50,620 moment. If you're looking for an extended warranty for your rv, 13 00:00:50,700 --> 00:00:54,460 whether you're buying new used private party or from a dealership, 14 00:00:54,940 --> 00:01:00,310 wholesale warranties can help you out. Use the link in the description, 15 00:01:00,310 --> 00:01:04,910 this podcast and go to their website and talk to them, see what 16 00:01:04,910 --> 00:01:08,470 they can do for you. They always have a great offer. They're 17 00:01:08,470 --> 00:01:11,630 always taking care of their customers. And their extended warranties, 18 00:01:12,350 --> 00:01:15,470 I'm not going to say are flawless. But before you ever sign 19 00:01:15,470 --> 00:01:19,590 up, you know what you're getting. They tell you up front what 20 00:01:19,590 --> 00:01:22,630 it's going to cover and more importantly, what it's not going 21 00:01:22,630 --> 00:01:26,360 to cover. So sometimes we don't think about things unless it's 22 00:01:26,360 --> 00:01:30,080 said. You know, we think, oh, transmission is covered. So that 23 00:01:30,080 --> 00:01:34,760 would mean the drive shaft, the rear differential. Not necessarily. 24 00:01:35,240 --> 00:01:39,040 So they tell you all that up front so you know beforehand. So 25 00:01:39,040 --> 00:01:42,120 go to wholesale warranties. Like I said, the link's in the description. 26 00:01:42,840 --> 00:01:47,920 Talk to them first. It costs you nothing. It'll be painless. It'll 27 00:01:47,920 --> 00:01:51,000 be less pain talking to them than buying that rv. Believe me, 28 00:01:52,100 --> 00:01:54,980 that I can guarantee. All right, now that's going to bring 29 00:01:54,980 --> 00:01:59,580 us sustain on the road. I shouldn't make that sound so bad. 30 00:01:59,580 --> 00:02:02,060 Like buying an RV is going to be the most painful thing in the 31 00:02:02,060 --> 00:02:05,540 world. But you know, the moment you walk into a dealership, 32 00:02:05,540 --> 00:02:10,540 whether it's car or rv, the pain just starts, right? What am 33 00:02:10,540 --> 00:02:16,220 I doing here? Been there myself many times. All right, so 34 00:02:16,220 --> 00:02:19,540 let's talk about your RV furnace problems. Should you maintain 35 00:02:19,540 --> 00:02:25,010 it, repair or replace your RV furnace? You know, usually the furnace 36 00:02:25,010 --> 00:02:27,690 doesn't get a whole lot of attention. It just sits in that RV 37 00:02:27,690 --> 00:02:31,730 and does nothing until you're ready to use it. And then you want 38 00:02:31,730 --> 00:02:35,850 that bad boy to work. Come on, baby. You hit the thermostat Fire 39 00:02:35,850 --> 00:02:42,210 up and nothing happens. There's no heat. And then all of 40 00:02:42,210 --> 00:02:45,370 a sudden, it's the questions. Oh, my gosh, what is it? Is it me? 41 00:02:45,370 --> 00:02:50,050 Did I not maintain it? Is it me? Are we breaking up furnace? No, 42 00:02:50,650 --> 00:02:54,690 it's not you. It could be maintenance, but more than likely 43 00:02:54,690 --> 00:02:57,570 it's just the furnace that's having a bad day and it doesn't want 44 00:02:57,570 --> 00:03:01,690 to start. So that's what we're going to talk about today. We're 45 00:03:01,690 --> 00:03:04,570 going to walk through this and determine whether it's worth repairing 46 00:03:04,730 --> 00:03:08,450 or replacing. So that being said, you know, you're not going 47 00:03:08,450 --> 00:03:12,970 to walk away with it from this episode as a RV furnace technician. 48 00:03:13,210 --> 00:03:16,970 We're just exploring it because that question comes up so 49 00:03:16,970 --> 00:03:20,960 much. Should I just buy a new furnace? That question comes up all 50 00:03:20,960 --> 00:03:23,720 the time. So that's what we're going to discuss today and break 51 00:03:23,720 --> 00:03:27,240 it down so you can make an informed decision in the future. 52 00:03:27,800 --> 00:03:30,360 But there are some basic things we're going to walk through 53 00:03:30,680 --> 00:03:33,919 to help you determine whether your furnace is worth repairing, 54 00:03:33,919 --> 00:03:37,760 not repairing. And it's going to be maybe a little slow going for 55 00:03:37,760 --> 00:03:40,520 some because maybe you already know this, you understand it, but 56 00:03:40,520 --> 00:03:44,960 this podcast is for everybody. New RVers, you know, been RVing for 57 00:03:44,960 --> 00:03:49,360 an hour. Those been RVing for 100 years. It doesn't matter. And 58 00:03:49,360 --> 00:03:51,760 you know what, we can always learn something. Something will be 59 00:03:51,760 --> 00:03:55,160 said that's going to jog your memory. Oh, yeah, yeah, okay, I remember 60 00:03:55,160 --> 00:03:58,240 that. Okay, that's a good one to know. Let's understand just how 61 00:03:58,240 --> 00:04:01,760 a furnace works. Now. Think of the thermostat as an on off switch. 62 00:04:01,760 --> 00:04:05,880 And that's it. It's just an on off switch. So you turn the thermostat 63 00:04:05,880 --> 00:04:09,600 on. So basically that's what is called a call for heat. So you 64 00:04:09,600 --> 00:04:12,360 have to have 12 volt power. So there's four things here. You have 65 00:04:12,540 --> 00:04:16,380 turn the thermostat on. You have to have 12 volt power, you have 66 00:04:16,380 --> 00:04:19,940 to have good propane, and you have to have proper airflow through 67 00:04:19,940 --> 00:04:24,220 the combustion chamber and the interior sides of the rv. So the 68 00:04:24,220 --> 00:04:27,980 furnace has to have air flowing through it. And that 12 volt 69 00:04:27,980 --> 00:04:32,980 requirement is a requirement. Sometimes we think that, oh, well, 70 00:04:32,980 --> 00:04:37,100 my RV is plugged in the 12v good. And it's not always good. Your 71 00:04:37,100 --> 00:04:41,240 lights might be on, but you could have other problems. And trust 72 00:04:41,240 --> 00:04:44,640 me, it happens. And I've said this so many times talking about 73 00:04:44,640 --> 00:04:50,200 batteries in RVs and 12 volts. So just reiterating that. All right, 74 00:04:50,200 --> 00:04:53,240 so you want to make sure you have good 12 volts going to the battery. 75 00:04:54,120 --> 00:04:59,360 Now, if you have all four of those things in place, then here's 76 00:04:59,360 --> 00:05:02,680 what should happen. When the furnace starts, you turn the thermostat 77 00:05:02,680 --> 00:05:06,880 on. The circuit board gets that information. Then the blower 78 00:05:06,880 --> 00:05:10,790 motor starts. Within, you know, 15 seconds or so, 10 seconds, 79 00:05:10,790 --> 00:05:14,150 it kicks on. And then it's going to go through the cycles of 80 00:05:14,150 --> 00:05:17,430 trying to light. So as it goes through those cycles, you can hear 81 00:05:17,430 --> 00:05:20,950 the maybe hear the gas valve open. You might hear some clicking 82 00:05:20,950 --> 00:05:25,150 like, like the igniters trying to light. You may or may not hear 83 00:05:25,150 --> 00:05:28,030 those things, but when it lights, you definitely hear a change 84 00:05:28,030 --> 00:05:33,710 in the sound. You hear the flame kick on, sounds like afterburners 85 00:05:33,710 --> 00:05:38,870 kicking in. And that's after it lights. After the furnace is told 86 00:05:38,870 --> 00:05:42,980 by the flames or the tail switch that, hey, the airflow is 87 00:05:42,980 --> 00:05:46,180 good, the blower motor spinning, open up the gas valve, 88 00:05:46,260 --> 00:05:50,540 start lighting, and then it does. And then it stays lit. As long 89 00:05:50,540 --> 00:05:54,700 as the electrode or the flame sensor is working properly, it sends 90 00:05:54,700 --> 00:05:59,140 a signal back to the circuit board. Everything's go here. And 91 00:05:59,140 --> 00:06:02,020 so the circuit board just keeps on going, keeps feeding it 92 00:06:02,020 --> 00:06:06,380 fuel if needed, more spark. If you know the flame went out for some 93 00:06:06,380 --> 00:06:10,690 reason, the fuel supply cut off for a moment, whatever it might 94 00:06:10,690 --> 00:06:14,450 be, it'll kick back on. So everything's in motion, everything's 95 00:06:14,450 --> 00:06:18,290 good. But when something happens in that sequence, sail switch 96 00:06:18,290 --> 00:06:21,210 isn't working right, circuit board is not working right, gas valves 97 00:06:21,210 --> 00:06:26,130 not working right, then things start falling apart, like, oh, the 98 00:06:26,130 --> 00:06:29,290 furnace isn't working. And then we say, is it me? Did I do something? 99 00:06:29,450 --> 00:06:32,410 Why are you leaving me furnace? Why aren't you working? 100 00:06:33,700 --> 00:06:38,300 Just kidding. All right, so we might start thinking about maintenance. 101 00:06:38,300 --> 00:06:42,500 And that's cool. You know, maintenance is good, but on a furnace, 102 00:06:42,500 --> 00:06:46,460 there's only so much maintenance that can be done. And 103 00:06:46,460 --> 00:06:49,900 then even some of the things I'm going to talk about here, you 104 00:06:49,900 --> 00:06:52,940 know, they might be. Well, if you've owned your RV for 10 years, 105 00:06:52,940 --> 00:06:55,580 you know, everything works, the furnace has always worked, and 106 00:06:55,580 --> 00:06:59,700 you know your ducting's all in shape, then you might not have any 107 00:06:59,700 --> 00:07:02,920 problems with any of that. You might not even consider it. But if 108 00:07:02,920 --> 00:07:07,000 you just bought the RV and the furnace isn't working now, these 109 00:07:07,000 --> 00:07:10,040 might be some things you're going to look at. But the one area 110 00:07:10,120 --> 00:07:14,280 of maintenance you can do is all RVs have a return air grill inside 111 00:07:14,280 --> 00:07:18,960 them, generally lower by the refrigerator in the kitchen. You 112 00:07:18,960 --> 00:07:22,040 can take that grill off and just make sure there's nothing crazy 113 00:07:22,040 --> 00:07:24,880 going on there. Like if you have pets, if it's just jam packed 114 00:07:24,880 --> 00:07:29,360 with fur or, you know, mounds of dirt and dust. And yet sometimes 115 00:07:29,360 --> 00:07:33,200 it's surprising what you see inside these cabinets. I mean, sometimes 116 00:07:33,200 --> 00:07:36,800 you see literal dirt like it's never been cleaned, like someone's 117 00:07:36,800 --> 00:07:40,600 shoveling it in. That's the area where you can keep clean with 118 00:07:40,600 --> 00:07:43,680 a vacuum. You can vacuum that out. You can try to vacuum as much 119 00:07:43,680 --> 00:07:47,760 off the furnace as you can. And why, as I say that, it's making 120 00:07:47,760 --> 00:07:50,080 me think that there's basically two types of furnaces. 121 00:07:51,200 --> 00:07:54,120 There's the type that have a door on them that you access from 122 00:07:54,120 --> 00:07:57,080 the outside of the RV where you can do most of your repairs from 123 00:07:57,080 --> 00:08:00,000 the outside. The rv, so the furnace never has to be removed. 124 00:08:00,530 --> 00:08:03,970 Then there's the doorless models where everything. The furnace 125 00:08:03,970 --> 00:08:07,890 has to be removed to do any repairs on it. So depending on what 126 00:08:07,890 --> 00:08:12,090 you have, cleaning it out is going to be different. If you have 127 00:08:12,090 --> 00:08:14,530 a doored furnace, you can blow it out with air from the outside, 128 00:08:14,530 --> 00:08:18,570 get the blower wheel pretty clean. You can't clean the backside 129 00:08:18,570 --> 00:08:21,410 from the outside, but you can go inside and clean the backside. 130 00:08:21,650 --> 00:08:24,730 But they're all in a case, so it's harder to do. But anyways, if 131 00:08:24,730 --> 00:08:29,060 you keep that area clean, that's part of the battle. Now the 132 00:08:29,060 --> 00:08:32,700 other thing is making sure that there's good airflow. And that's 133 00:08:32,700 --> 00:08:36,460 one thing that's very important. Now, RVs have flexible 134 00:08:36,460 --> 00:08:40,340 ducting in them, and it goes from the furnace out to wherever 135 00:08:40,340 --> 00:08:43,620 it's going to go. Bedroom, bathroom, kitchen, living room. Every 136 00:08:43,620 --> 00:08:46,620 RV is a little bit different. Some have a duct going to compartments. 137 00:08:47,420 --> 00:08:51,340 So just learn your system. Where's the ducting? Is it in places 138 00:08:51,340 --> 00:08:53,820 where if I were to put something different in a cabinet, 139 00:08:54,180 --> 00:08:58,980 is it going to smash it? Will it cause a problem in the cabinet 140 00:08:58,980 --> 00:09:02,300 or the ducting? In other words, if I put bigger pans in there 141 00:09:02,300 --> 00:09:05,700 now and I push them in and shut the door, am I smashing some 142 00:09:05,700 --> 00:09:09,700 ducting? Now the ducting generally is not exposed like that. 143 00:09:09,700 --> 00:09:12,940 But like I said, every RV is different. It just depends on how 144 00:09:12,940 --> 00:09:17,540 they ran. Could be things under a kitchen sink, it could be 145 00:09:17,620 --> 00:09:21,730 something anywhere. So just being familiar with that and also 146 00:09:21,730 --> 00:09:26,410 knowing that if there's a kink in the ducting, you know, you push 147 00:09:26,410 --> 00:09:30,730 something in, it kinks it. That can be the problem. Or if you're 148 00:09:30,730 --> 00:09:33,770 stacking stuff in front of the return air grill, maybe your kids 149 00:09:33,770 --> 00:09:36,610 are come up for the weekend, you get the trailer ready for them, 150 00:09:37,089 --> 00:09:39,650 they say in it the entire time they're there, they're complaining 151 00:09:39,650 --> 00:09:42,730 about the furnace not working properly, and you never really think 152 00:09:42,730 --> 00:09:45,090 about. You go, okay, well, I'll just deal with it and I'll, 153 00:09:45,090 --> 00:09:47,810 you know, as long as you're good, you know, here's electric heater 154 00:09:47,810 --> 00:09:50,340 if you need it. So after they leave, you go turn on the furnace, 155 00:09:50,340 --> 00:09:54,780 and it works perfect. What's going on? Maybe they stack some stuff 156 00:09:54,780 --> 00:09:58,260 in front of that return air, grill some cases of water, some of 157 00:09:58,260 --> 00:10:01,260 their luggage, some things like that. So it's cutting down that 158 00:10:01,260 --> 00:10:04,260 airflow and the furnace isn't going to work. Right. Or they put 159 00:10:04,260 --> 00:10:07,860 some things over a duct. Sometimes if you turn off one duct 160 00:10:07,860 --> 00:10:11,060 in an rv, that's it. The furnace won't work right because 161 00:10:11,060 --> 00:10:15,890 it's. They have the minimal amount of ducting in there, or maybe 162 00:10:15,890 --> 00:10:18,690 some of the other ducting was run poorly. So you turn off one, 163 00:10:18,690 --> 00:10:22,050 it just affects the whole furnace. And, you know, they don't 164 00:10:22,050 --> 00:10:25,490 run ducting like they should in all RVs. They don't do a lot of 165 00:10:25,490 --> 00:10:29,610 things like they should in all RVs. I have something rolling around 166 00:10:29,610 --> 00:10:32,050 here in my mind about mine, but I'm not going to say it yet. 167 00:10:32,050 --> 00:10:35,930 It's a. It's a Heartland trailer, you know, not going there. 168 00:10:36,170 --> 00:10:39,610 But things aren't always done the way they should be. But we know 169 00:10:39,610 --> 00:10:43,400 that when we bought the RV and we just deal with it. So don't expect 170 00:10:43,400 --> 00:10:47,400 it to be perfect. And if you find flaws, just repair them, move 171 00:10:47,400 --> 00:10:51,280 on with life. Right. And don't forget to inspect the outside of 172 00:10:51,280 --> 00:10:55,720 the RV as well. The furnace has a. An exhaust and an intake out 173 00:10:55,720 --> 00:10:57,680 there, so you want to make sure there's nothing in there. No 174 00:10:57,680 --> 00:11:02,280 nest, no bugs, no anything. There's not debris building up over 175 00:11:02,280 --> 00:11:05,480 the little vent or the COVID on the vent. Make sure before you 176 00:11:05,480 --> 00:11:09,690 check that out that you turn off the furnace and it's cooled down 177 00:11:09,690 --> 00:11:12,770 so you're not getting burning your hand by touching it. Because 178 00:11:12,770 --> 00:11:15,450 that vent on the outside can get pretty darn hot. So you want 179 00:11:15,450 --> 00:11:18,490 to make sure that's clean. In fact, they make little screens you 180 00:11:18,490 --> 00:11:22,130 put over your exhaust vents that keep stuff from going in there 181 00:11:22,130 --> 00:11:25,250 to help reduce that problem. Because in some areas it can be a 182 00:11:25,250 --> 00:11:29,290 problem. And sometimes just any little thing in there can create 183 00:11:29,610 --> 00:11:33,370 a disaster or something can work its way in, actually to the 184 00:11:33,370 --> 00:11:38,900 burner area. And just a little like a moth, a leaf, can just ruin 185 00:11:38,900 --> 00:11:43,180 the airflow and cause problems. Now, sometimes we hear 186 00:11:43,180 --> 00:11:46,140 things in the RV and we don't pay a lot of attention to it. Oh, 187 00:11:46,140 --> 00:11:49,260 well, it sounds like the furnace is making noise. Well, that 188 00:11:49,260 --> 00:11:52,300 could be the blower. And something could be wrong with the 189 00:11:52,300 --> 00:11:55,340 blower. You know, the motor could be going bad. There could be 190 00:11:55,340 --> 00:11:59,620 something in the blower wheel, it's making noise. All these things 191 00:11:59,700 --> 00:12:03,100 indicate there's a problem brewing and you need to take care 192 00:12:03,100 --> 00:12:07,150 of it. You don't want to just blow that off and, oh, well, eventually 193 00:12:07,150 --> 00:12:09,870 it'll work itself out. That'll work itself out when the furnace 194 00:12:09,870 --> 00:12:14,070 was working, right? And you know, it could be anything in there 195 00:12:14,070 --> 00:12:17,670 as well. I mean, it could be mice, could be dirt, could be leaves, 196 00:12:17,750 --> 00:12:22,030 could be who knows what, gobs of hair. Maybe the people own the 197 00:12:22,030 --> 00:12:25,990 RV before you, if you've just bought it, had some pets, and they 198 00:12:25,990 --> 00:12:28,950 cleaned it up really good so you couldn't tell that. But the furnace 199 00:12:28,950 --> 00:12:32,810 will give it all away, right? So you could have a lot of pet hair 200 00:12:32,810 --> 00:12:37,770 in there. And one other thing, to make sure that your LP detector, 201 00:12:37,850 --> 00:12:41,370 smoke detector, and your carbon monoxide alarm is all working, 202 00:12:42,410 --> 00:12:45,810 that everything's good. Most of the carbon monoxide detectors 203 00:12:45,810 --> 00:12:50,730 are hardwired into the RV's 12 volt system. And, you know, the smoke 204 00:12:50,730 --> 00:12:53,530 detectors might have batteries in them, but make sure everything's 205 00:12:53,530 --> 00:12:58,410 good. You don't want to die because of a furnace. You know, your 206 00:12:58,410 --> 00:13:01,730 carbon monoxide detector is not working. Your furnace malfunctions 207 00:13:01,730 --> 00:13:06,010 and you get carbon monoxide poisoning thing going on. And it 208 00:13:06,010 --> 00:13:10,890 does happen, and people die in RVs because of it. Now if that happens 209 00:13:10,890 --> 00:13:14,210 to you, you won't know it because you won't wake up from your 210 00:13:14,210 --> 00:13:18,250 sleep. So we want you to wake up, we want you and your family to 211 00:13:18,250 --> 00:13:22,450 wake up. So spend the hundred bucks if yours is defective and replace 212 00:13:22,450 --> 00:13:27,860 that detector. So don't go cheap on that one. Now, when a furnace 213 00:13:27,860 --> 00:13:30,420 probably needs repairs, there's generally signs. You know, 214 00:13:30,420 --> 00:13:33,500 obviously it's not working, things are happening. You've checked 215 00:13:33,500 --> 00:13:35,900 all the ducting and those type of things. But we're going to go 216 00:13:35,900 --> 00:13:41,260 on to the more, I guess, specific things now. So you go to 217 00:13:41,260 --> 00:13:44,740 the furnace, you turn on the thermostat, and nothing happens. 218 00:13:44,740 --> 00:13:48,660 I mean, nothing happens. And I want to qualify that because I hear 219 00:13:48,660 --> 00:13:51,690 that a lot. We ask the customers, well, what, what happens 220 00:13:51,690 --> 00:13:55,810 when you turn thermostat on? They say nothing. Then you keep going 221 00:13:55,810 --> 00:13:59,450 it. Well, the blower wheel comes on, the fan spins, it makes 222 00:13:59,450 --> 00:14:04,570 noise. Okay, so the fan does or the fairness does something. And 223 00:14:04,570 --> 00:14:07,410 there's a difference there between the fan coming on and not 224 00:14:07,410 --> 00:14:10,690 coming on. It's part of the diagnosing the problem. So in this 225 00:14:10,690 --> 00:14:14,050 case, nothing comes on, there's no noise, the furnace doesn't, 226 00:14:14,450 --> 00:14:17,990 the fan doesn't spin, nothing happens. That could be a battery 227 00:14:17,990 --> 00:14:20,710 problem. You know, low voltage, not getting charged. The 228 00:14:20,710 --> 00:14:24,070 battery is bad. And we're just going to go with that. You know, 229 00:14:24,070 --> 00:14:26,550 if the converter could be an issue, we're not going to get all 230 00:14:26,550 --> 00:14:31,190 the little tentacles that where this can go. The fuse could 231 00:14:31,190 --> 00:14:34,510 be bad. You know, you could have a bad battery ground. The thermostat 232 00:14:34,510 --> 00:14:39,070 could be failing. You know, is power getting to the furnace? Is 233 00:14:39,070 --> 00:14:45,170 the on off switch on or you. Yeah. Now most furnaces have this 234 00:14:45,170 --> 00:14:50,050 on off switch or a reset switch. And if it's a doored furnace, 235 00:14:50,130 --> 00:14:52,210 they're very accessible because you open up the door and 236 00:14:52,210 --> 00:14:55,490 it's right there. But if it's not a doored furnace and you haven't 237 00:14:55,490 --> 00:14:57,850 been touching the furnace, trying to get your arm in there and 238 00:14:57,850 --> 00:15:01,450 see if you can feel something, that switch should just be in the 239 00:15:01,450 --> 00:15:05,330 on position. If you know it worked, let's say the day before 240 00:15:05,730 --> 00:15:09,330 a week ago, there's no way that switch is just going to turn 241 00:15:09,330 --> 00:15:12,330 itself off. Now the switch could go bad. I'm not saying that 242 00:15:12,330 --> 00:15:16,470 could to be an issue, but making sure there's power. See, that's 243 00:15:16,470 --> 00:15:19,510 where that power comes in. And by the way, we're not going to go 244 00:15:19,510 --> 00:15:23,110 down all the roads exploring what the problems each one of these 245 00:15:23,110 --> 00:15:26,350 problems could be, you know, where it starts and where it could 246 00:15:26,350 --> 00:15:32,070 end. Because there it's just a broad diagnosis. Here it's getting 247 00:15:32,230 --> 00:15:35,470 started. So like, let's say you called me and said, hey Eric, 248 00:15:35,470 --> 00:15:37,990 this is what's going on with my furnace. I started asking you 249 00:15:37,990 --> 00:15:41,460 questions and we would dial it in a little bit more. We'd get pretty 250 00:15:41,460 --> 00:15:46,380 darn close on each diagnosis and what's going on, each symptom 251 00:15:46,620 --> 00:15:50,060 and getting you closer to that problem. And we'd walk you right 252 00:15:50,060 --> 00:15:54,460 into the problem. But just for the sake of this, we're just covering 253 00:15:54,460 --> 00:15:57,460 what it could be and it actually gives you a good idea where 254 00:15:57,460 --> 00:16:01,300 to go with this. And by the way, most furnace manufacturers and 255 00:16:01,300 --> 00:16:06,340 their manuals have a tree that walks you through the problems, explains 256 00:16:06,340 --> 00:16:09,780 what to check here, what to check there. Power here, go there, 257 00:16:10,020 --> 00:16:13,860 no power here, go here. And they're very helpful. And when you 258 00:16:13,860 --> 00:16:17,220 understand how one furnace works, it kind of explains how all 259 00:16:17,220 --> 00:16:20,940 furnace works. In RVs, they're very similar. They have some subtle 260 00:16:20,940 --> 00:16:23,980 differences, but overall they're very similar. And keep in 261 00:16:23,980 --> 00:16:27,660 mind too, at low battery so if your battery's weak, you know, the 262 00:16:27,660 --> 00:16:32,420 lights might be on inside, but the battery might not be strong enough 263 00:16:32,420 --> 00:16:36,170 to run the furnace. You know enough battery life to run the lights, 264 00:16:36,170 --> 00:16:40,730 but not the furnace. Especially with LED lights, they 265 00:16:40,730 --> 00:16:44,170 don't draw nearly as much. So it can be a little deceptive. So 266 00:16:44,170 --> 00:16:47,890 don't lose. Use your lights as a gauge. Use an actual multimeter 267 00:16:47,890 --> 00:16:51,610 to check things out. And I've emphasized it in the past, a multimeter 268 00:16:51,610 --> 00:16:55,890 is a must have for every RVer. Now let's look at some possibilities 269 00:16:55,970 --> 00:17:01,740 that let's say you turn the thermostat on, you wait a few seconds 270 00:17:01,740 --> 00:17:06,420 and the blower starts up, but the furnace doesn't light. In fact, 271 00:17:06,420 --> 00:17:09,420 it goes through its three, it tries to light three times, it goes 272 00:17:09,420 --> 00:17:13,700 through its cycle and then it shuts off. That shutting off is not 273 00:17:13,700 --> 00:17:17,900 a symptom. That's what it's supposed to do. And a lot of people 274 00:17:17,900 --> 00:17:22,100 will stop right after that and give up, like up. And maybe they 275 00:17:22,100 --> 00:17:24,780 just switched out to propane tanks and the furnace just wasn't 276 00:17:24,780 --> 00:17:28,540 getting the propane it needed. So you need to turn the thermostat 277 00:17:28,540 --> 00:17:32,620 off and turn all the way off and turn it back on again and that'll 278 00:17:32,620 --> 00:17:36,820 reset the circuit board and it can try again. You know, you do that 279 00:17:36,820 --> 00:17:39,860 two or three times and it doesn't light. Well, there's a problem, 280 00:17:39,860 --> 00:17:42,900 especially if you check the stove for propane. Your water heater 281 00:17:42,900 --> 00:17:46,460 is working then. Yeah, there's something wrong with the furnace. 282 00:17:46,460 --> 00:17:49,820 It's just going through a light up cycle. But since it doesn't 283 00:17:49,820 --> 00:17:53,700 light up, it just stops. It's not going to keep doing that. So 284 00:17:53,700 --> 00:17:59,580 that could be low voltage. The blower speeds knocking up to. Or 285 00:17:59,580 --> 00:18:03,740 the blower is knocking up to speed to engage the sail switch. 286 00:18:04,780 --> 00:18:08,420 The sail switch could be bad. It could have dirt inside of it, 287 00:18:08,420 --> 00:18:11,180 some lint. It could have, you know, many things going on with it 288 00:18:11,180 --> 00:18:15,420 that could be failing, causing to fail, not work properly. There 289 00:18:15,420 --> 00:18:18,300 could be restricted airflow, but hopefully we've already ruled 290 00:18:18,300 --> 00:18:23,370 that out and I that's probably not going to tie into this, at least 291 00:18:23,370 --> 00:18:26,650 not very often. Usually it's just a problem within the furnace, 292 00:18:26,650 --> 00:18:31,490 not an airflow issue, but it could be. So just take a quick check 293 00:18:31,650 --> 00:18:35,490 to make sure there's nothing blocking the air intake or the exhaust. 294 00:18:35,890 --> 00:18:39,450 And by the way, some furnaces, if you have them apart, you're testing 295 00:18:39,450 --> 00:18:42,690 on the workbench, sometimes you have to put an exhaust tube on 296 00:18:42,690 --> 00:18:46,970 the exhaust to extend it out past the back of the furnace to Simulate 297 00:18:46,970 --> 00:18:50,050 being an rv, because if it's not extended, the furnace will shut 298 00:18:50,050 --> 00:18:52,730 off very quickly because it starts pulling that in and that doesn't 299 00:18:52,730 --> 00:18:56,770 work. That's a little sidebar there, but just keep that in mind. 300 00:18:57,170 --> 00:18:59,690 You can actually use. If you take your furnace out, you can use 301 00:18:59,690 --> 00:19:02,690 the vent that comes out on the side of your rv or just get a pipe 302 00:19:02,690 --> 00:19:05,410 and put it over the exhaust. It's more likely not going to be 303 00:19:05,410 --> 00:19:08,370 airflow. The motor could be just running slow. So it could be 304 00:19:08,370 --> 00:19:11,570 going bad. It's not an everyday occurrence. That happens 305 00:19:12,360 --> 00:19:16,560 generally in a lot of cases, it's just a sail switch. So there's 306 00:19:16,560 --> 00:19:20,080 little things there that can give it away. But you know, we're 307 00:19:20,080 --> 00:19:24,480 getting close to it, right? Could be wiring, could be a circuit 308 00:19:24,480 --> 00:19:27,400 board problem. And sometimes circuit boards will be the problem. 309 00:19:27,719 --> 00:19:31,200 When it doesn't seem like it will be vice versa. It could be a 310 00:19:31,200 --> 00:19:35,320 sail switch, and sometimes it doesn't seem like it will be. Now, 311 00:19:35,320 --> 00:19:41,090 let's say you turn on the thermostat and the furnace fan spins 312 00:19:41,090 --> 00:19:45,410 up, gets the speed. You hear the furnace clicking, but it doesn't 313 00:19:45,410 --> 00:19:50,330 light. So what could that be? So that could mean that the sail 314 00:19:50,330 --> 00:19:53,970 switch is telling the circuit board, hey, I'm closed. Open that 315 00:19:53,970 --> 00:19:57,850 gas valve and start sparking. Well, the circuit board is going 316 00:19:57,850 --> 00:20:01,650 to send power to the gas valve, and it's going to start sparking, 317 00:20:01,650 --> 00:20:05,970 start igniting. But if the gas valve isn't working right, that power 318 00:20:05,970 --> 00:20:08,370 is not going to do anything other than just go to the gas valve. 319 00:20:08,370 --> 00:20:10,870 And the circuit board doesn't know that there's a problem with 320 00:20:10,870 --> 00:20:15,230 the gas valve per se. But after it doesn't light, eventually, 321 00:20:15,230 --> 00:20:18,070 you know, after three times of going through the ignition cycle, 322 00:20:18,230 --> 00:20:24,150 it's going to turn off and go into lockout mode. So the gas valve 323 00:20:24,150 --> 00:20:28,430 could be getting power but not opening like it should. You know, 324 00:20:28,430 --> 00:20:32,710 the igniter could be bad. The flame sensor could be bad, or the. 325 00:20:32,710 --> 00:20:36,240 Well, I'm going to stick with the igniter could be bad. The burner 326 00:20:36,320 --> 00:20:40,000 could have some debris in it that's keeping it from lighting. 327 00:20:40,400 --> 00:20:43,520 You might hear little puffs, little light for a split second. 328 00:20:44,320 --> 00:20:49,520 That could be some leaves in the gas in the burner area. The burner 329 00:20:49,520 --> 00:20:53,120 itself could just be bad. It could be burned out, rusted through. 330 00:20:54,320 --> 00:20:58,120 Could be electrical problem, could be a propane issue. So make 331 00:20:58,120 --> 00:21:01,640 sure your water heater and stove are working. Could be the circuit 332 00:21:01,640 --> 00:21:05,700 board. And anytime you suspect a circuit board, I would imagine 333 00:21:05,700 --> 00:21:09,100 most RV stores would check them at no charge. I know we do we 334 00:21:09,100 --> 00:21:13,300 always have? And that seems to be a normal thing, but maybe not. 335 00:21:13,860 --> 00:21:17,260 Haven't been out in the wild and had that done. But you can tell 336 00:21:17,260 --> 00:21:21,620 me about that anytime. Just use the con. The comments check comments 337 00:21:21,620 --> 00:21:26,140 section of our website, the smartrver.com okay, so now what happens 338 00:21:26,140 --> 00:21:29,820 when the burner lights and then the flame just shuts off, lights 339 00:21:29,820 --> 00:21:34,160 up for a few seconds and turns off one or two seconds, maybe three, 340 00:21:34,800 --> 00:21:38,320 so it doesn't stay lit. So again, that could be an electrode 341 00:21:38,320 --> 00:21:43,440 issue. Could be, actually be a poor ground electrical connection, 342 00:21:44,480 --> 00:21:50,640 which those are not as common, but they are out there. And so you'll 343 00:21:50,640 --> 00:21:53,320 hear someone say that and don't dismiss it when they say it. 344 00:21:53,320 --> 00:21:55,640 If you're talking to a technician, well, it could be a poor 345 00:21:55,640 --> 00:21:59,560 ground. You know, it almost sounds like a scapegoat excuse. Oh, 346 00:21:59,560 --> 00:22:02,480 yeah, get this person out of here. But it's not. There can be 347 00:22:02,480 --> 00:22:06,190 electrical problems. The propane pressure could be off. So 348 00:22:06,190 --> 00:22:08,630 make sure your water heater and a circuit board work. If you 349 00:22:08,630 --> 00:22:12,150 don't have a way to test the pressure of the propane. Again, it 350 00:22:12,150 --> 00:22:16,870 could be a circuit board, you know, but that flame sensor or electrode, 351 00:22:16,870 --> 00:22:20,230 they're combined into one these days. So the electrode is the 352 00:22:20,230 --> 00:22:23,750 flame sensor. If it doesn't sense the flame, and what it does 353 00:22:23,750 --> 00:22:26,590 is it sends a pulse, electrical pulse, back down to the 354 00:22:26,590 --> 00:22:30,310 circuit board. Then the circuit board says up, we got to 355 00:22:30,310 --> 00:22:32,830 shut you off. We got to turn everything off because we don't want 356 00:22:32,830 --> 00:22:37,630 this RV to blow up. So that's what it's going to do. So the flame 357 00:22:37,630 --> 00:22:41,630 sensor is a safety device, but it also, in this case, will light 358 00:22:41,630 --> 00:22:45,670 the furnace. It's the electrode flame sensor. And most 359 00:22:45,670 --> 00:22:48,870 people look at that like those never go bad. You're crazy when you 360 00:22:48,870 --> 00:22:52,990 say it, but they do go bad. They do have problems. Not always. 361 00:22:53,070 --> 00:22:56,230 And I think the thing is some, on some furnaces, they're a pain 362 00:22:56,230 --> 00:22:59,670 to replace. They take a little more time because you got to take 363 00:22:59,670 --> 00:23:02,590 much more of the furnace apart than, you know, one brand versus 364 00:23:02,590 --> 00:23:06,850 the other. Then it's like, well, if we got to do that, I really 365 00:23:06,850 --> 00:23:10,690 don't want to do it. And my take is if you do it, just get the 366 00:23:10,690 --> 00:23:13,970 new one and put it in regardless. You take the other one 367 00:23:13,970 --> 00:23:16,890 out, it looks okay. You can't see anything obvious. Just put a 368 00:23:16,890 --> 00:23:21,130 new one in and check the spark before you put it all back together. 369 00:23:21,130 --> 00:23:25,410 If you can. Most furnaces, you can do that. You can hook them up 370 00:23:25,410 --> 00:23:28,210 and let it go through its motions without propane. To it and 371 00:23:28,210 --> 00:23:33,360 make sure that it is sparking properly. Now if your furnace comes 372 00:23:33,360 --> 00:23:38,440 on, it lights then shuts off, comes on, shuts off. Short cycling 373 00:23:38,440 --> 00:23:42,080 as they call it. You know, that's not as common. It could be 374 00:23:42,080 --> 00:23:46,000 a restricted return air grill, could be an airflow problem. You 375 00:23:46,000 --> 00:23:48,840 know, all the things we talked about in the beginning. The high 376 00:23:48,840 --> 00:23:52,680 temperature limit switch could actually be bad cycling more than 377 00:23:52,680 --> 00:23:56,320 it should. Could be a thermostat location, but probably 378 00:23:56,320 --> 00:23:59,900 not because you've already had this RV for some time. Could be a 379 00:23:59,900 --> 00:24:02,820 loose wire, maybe in the thermostat, it could be a bad wire 380 00:24:02,820 --> 00:24:06,820 someplace else. But you know, if the RV sitting still, sometimes 381 00:24:06,820 --> 00:24:09,980 that can be very hard to find. You know, there's a lot of things 382 00:24:10,060 --> 00:24:14,020 that can be that are not normal. Because you've already had 383 00:24:14,020 --> 00:24:19,100 this rv, I'm assuming even if it's a new RV or you know, new to 384 00:24:19,100 --> 00:24:23,260 you, a brand new rv. Yeah. First time you light up the furnace 385 00:24:23,260 --> 00:24:25,540 and you know there's all these odd things going on. It definitely 386 00:24:25,540 --> 00:24:29,310 could be the ducting, return al, grill, anything, because the 387 00:24:29,310 --> 00:24:32,510 manufacturer could have just done it wrong. But the chances that 388 00:24:32,510 --> 00:24:36,230 like buying a 10 or 15 year old RV and they live in cold country 389 00:24:36,230 --> 00:24:38,750 at the furnace doesn't work properly and they just let it go 390 00:24:38,750 --> 00:24:41,910 for all those years, it's pretty slim. So it's probably not 391 00:24:41,910 --> 00:24:46,030 going to be a obscure problem. Although it can be. I mean sometimes 392 00:24:46,030 --> 00:24:51,310 furnaces a very simple little appliance, they can have nightmarish 393 00:24:51,310 --> 00:24:55,480 type problems to figure out. But inspect these things. Don't just 394 00:24:55,480 --> 00:24:58,640 automatically condemn the furnace. Because I know people have 395 00:24:58,640 --> 00:25:04,080 bought furnaces thinking this will solve the problem and it doesn't. 396 00:25:04,320 --> 00:25:07,680 They buy a furnace and they don't realize that there's a ducting 397 00:25:08,080 --> 00:25:12,160 or some ducting that's been kinked, the blower or the ducting 398 00:25:12,160 --> 00:25:15,360 came off of the register. You know, it could be one of many things 399 00:25:15,360 --> 00:25:17,720 and they solve the same problem. They're all done. They just 400 00:25:17,720 --> 00:25:21,970 have a new furnace now and that's a lot of money to throw away. 401 00:25:21,970 --> 00:25:25,850 So make sure that, that if you replace the furnace, that you have 402 00:25:25,850 --> 00:25:28,890 good cause for that. And if you start hearing funny noises out 403 00:25:28,890 --> 00:25:32,210 of the furnace, definitely check it. You shouldn't hear any 404 00:25:32,210 --> 00:25:37,370 funny noises. The fan makes noise. When the flame comes on, that 405 00:25:37,370 --> 00:25:40,810 makes noise. You should hear those two things together all the 406 00:25:40,810 --> 00:25:44,250 time when the furnace is working properly. So when a repair 407 00:25:44,250 --> 00:25:47,090 makes sense is most of the time. I'm not going to break this 408 00:25:47,090 --> 00:25:50,960 down into every little thing, but generally the time when it's 409 00:25:50,960 --> 00:25:54,320 beyond repair. Is maybe you've just. You've put so much money in 410 00:25:54,320 --> 00:25:59,960 this furnace, it's, you know, 25 years old, and you've bought multiple 411 00:25:59,960 --> 00:26:02,800 circuit boards, you bought multiple blower motors. These problems 412 00:26:02,800 --> 00:26:06,680 just keep coming back. And as I say that, it makes me think about 413 00:26:06,680 --> 00:26:09,120 people living in their RVs. There's more people living in their 414 00:26:09,120 --> 00:26:14,240 RVs today. RVs are not meant to be lived in. So a furnace is going 415 00:26:14,240 --> 00:26:17,900 to age quicker with someone living in their rv. They're going 416 00:26:17,900 --> 00:26:20,380 to go through more parts. Doesn't mean you're going to have 417 00:26:20,380 --> 00:26:23,860 to replace the blower motor every year. It shouldn't be like 418 00:26:23,860 --> 00:26:28,780 that. But if you find yourself going through blower motors or circuit 419 00:26:28,780 --> 00:26:31,820 boards or it's just you're tired of all the problems with this 420 00:26:31,820 --> 00:26:35,220 furnace, or maybe it's 25 years old and you've bought all these 421 00:26:35,220 --> 00:26:38,340 parts maybe over the course of, you know, several years, maybe 422 00:26:38,340 --> 00:26:41,060 you've bought them twice. So, you know, I'm just going to put a 423 00:26:41,060 --> 00:26:44,780 new furnace in, and I might be. I might be doing the same thing, 424 00:26:44,780 --> 00:26:47,980 but sometimes it just feels good to just put something new in 425 00:26:47,980 --> 00:26:52,180 and get that thing out of the way. Starting out fresh, right? But 426 00:26:52,180 --> 00:26:57,060 ultimately, if you can still get parts for your furnace, and I 427 00:26:57,060 --> 00:27:00,540 mean all the parts, you know, you go to the parts counter and the 428 00:27:00,540 --> 00:27:02,900 guy looks up your furnace and you tell him, you know, I need a 429 00:27:02,900 --> 00:27:07,260 new blower wheel for it. Or let's say the fan motor, blower motor. 430 00:27:07,580 --> 00:27:10,780 And he looks up, okay, yeah, I can get one of those. In fact, I 431 00:27:10,780 --> 00:27:15,530 have it in stock here. He sells it to you for 200 bucks. And, 432 00:27:15,530 --> 00:27:20,770 you know, they can be 100, they can be 300, but you buy it and 433 00:27:20,850 --> 00:27:23,730 it gets you down the road for six months. You go back and, hey, 434 00:27:23,730 --> 00:27:27,410 I need a new burner now. My burner just, you know, destroyed. 435 00:27:28,129 --> 00:27:32,490 Oh, that's not available. Oh, really? How long have they not been 436 00:27:32,490 --> 00:27:35,650 available? Oh, for years. You know, just. We just happen to have 437 00:27:35,650 --> 00:27:38,860 that blower motor in stock. You. He didn't tell you that, right? 438 00:27:38,860 --> 00:27:42,940 He wanted to get that blower motor off the shelf. Always ask, 439 00:27:42,940 --> 00:27:46,020 are other parts available? If I need an igniter, could I get one 440 00:27:46,020 --> 00:27:48,700 today if I need a sail switch? And, you know, sometimes they can 441 00:27:48,700 --> 00:27:52,900 swap out other furnace parts to make your. Make yours work, but 442 00:27:52,900 --> 00:27:56,540 make sure parts are available, not just what you need that day. 443 00:27:56,940 --> 00:28:00,180 Because if you sink 200 bucks into blower motor and three weeks 444 00:28:00,180 --> 00:28:04,340 later, let's say the igniter goes bad, and. And you can't get 445 00:28:04,340 --> 00:28:08,580 one and you can't find one that will work to match it up. Now 446 00:28:08,580 --> 00:28:12,300 you're buying a new furnace. What a nightmare, right? So be sure 447 00:28:12,300 --> 00:28:16,180 of that. Now that's one thing. And the other thing is when there's 448 00:28:16,180 --> 00:28:19,100 a hole in the combustion chamber, when there's a hole in the 449 00:28:19,100 --> 00:28:22,100 combustion chamber, the furnace is done. Don't even think 450 00:28:22,100 --> 00:28:25,740 about repairing it. Regardless of who tells you what, just throw 451 00:28:25,740 --> 00:28:29,660 that furnace away and get a new one. And getting a new furnace, 452 00:28:29,660 --> 00:28:32,820 depending on what you have, could mean replacing the core of 453 00:28:32,820 --> 00:28:37,510 it. So it's the combustion chamber, the gas valve, all the components 454 00:28:37,510 --> 00:28:40,590 that make the heat, and it fits in your old cage. I call them 455 00:28:40,590 --> 00:28:44,070 a cage. The case that the furnace, you know, it slides into 456 00:28:44,470 --> 00:28:48,310 and it's a core and they're great, they work really nice. They're 457 00:28:48,790 --> 00:28:52,510 a lot less expensive than buying a complete furnace. But sometimes 458 00:28:52,510 --> 00:28:54,950 you have to go with a whole new furnace. And going with a whole 459 00:28:54,950 --> 00:28:59,110 new furnace, sometimes it's not always that easy. It's not a 460 00:28:59,110 --> 00:29:01,950 direct swap. And that's the other reason why you stick with your 461 00:29:01,950 --> 00:29:07,130 furnace if you can, you know, to replace it. You have to make sure 462 00:29:07,130 --> 00:29:10,170 everything's going to fall into place. The vents on the side 463 00:29:10,170 --> 00:29:13,450 of the rv, if you have a door, you have to get a doored furnace. 464 00:29:13,530 --> 00:29:16,530 You know, things have to line up. You have to have the same amount 465 00:29:16,530 --> 00:29:19,329 of space inside. Will the new furnace work? Will the amount of 466 00:29:19,329 --> 00:29:24,490 ducting I have or ducting work on it? So it's not just a go down 467 00:29:24,490 --> 00:29:28,370 and buy a new furnace. I mean, it's. Sometimes it's very easy to 468 00:29:28,370 --> 00:29:31,710 replace them, don't get me wrong. But there are times where 469 00:29:31,710 --> 00:29:36,670 you're trying to make it work and it can be a little more complicated. 470 00:29:37,390 --> 00:29:40,350 And you know, generally it's easier to go back with the same brand 471 00:29:40,350 --> 00:29:44,710 of furnace as well, because things will fit better. Not saying 472 00:29:44,710 --> 00:29:47,110 you have to do that and not saying that's going to be the case 473 00:29:47,110 --> 00:29:51,390 every time. So those your kind of go through it. Is your furnace, 474 00:29:51,390 --> 00:29:53,910 you know, is it something you're going to maintain, repair 475 00:29:53,910 --> 00:29:57,860 to places, hopefully that helps you make that decision. And 476 00:29:57,860 --> 00:30:01,940 in most cases, it's going to be, you know, repair it, maintain 477 00:30:01,940 --> 00:30:05,180 it, clean what you can, and repair it when you can. Just keep 478 00:30:05,180 --> 00:30:08,460 it working, stay ahead of any, any problems that start creeping 479 00:30:08,460 --> 00:30:12,100 their way in. So that way you're prepared. And believe me, 480 00:30:12,100 --> 00:30:15,260 a furnace, like anything else can go bad at any time. But the more 481 00:30:15,260 --> 00:30:18,140 you know about your furnace might save you some headaches. Even 482 00:30:18,140 --> 00:30:21,980 when you're out on the road, if the furnace stops working and 483 00:30:21,980 --> 00:30:24,340 it's a doored furnace, you can say, you know what, there's an RV 484 00:30:24,340 --> 00:30:26,660 store right there. I'm going to go see if they have a sail switch. 485 00:30:26,880 --> 00:30:28,920 I'm just going to throw in a sail switch. I'm going to do that, 486 00:30:28,920 --> 00:30:31,840 and I'm going to stop there if that isn't it or something else obvious. 487 00:30:32,480 --> 00:30:35,120 But at least you got a fighting chance to keep some heat 488 00:30:35,120 --> 00:30:38,400 going. All right, so that's going to conclude. Staying on the 489 00:30:38,400 --> 00:30:42,640 road. And so anything you, any questions about that, you can contact 490 00:30:42,720 --> 00:30:46,240 me directly. All the information will be on the podcast 491 00:30:46,480 --> 00:30:51,320 description, including a phone number and links to our website so 492 00:30:51,320 --> 00:30:54,480 you can get a hold of me. That brings us to quick tips. Should you 493 00:30:54,480 --> 00:31:00,750 replace your furnace with a Fogotti furnace? F O G A T T I Fogatti. 494 00:31:01,710 --> 00:31:05,990 Sounds like a Italian racing car, right? Well, it's not. It's 495 00:31:05,990 --> 00:31:11,950 a Chinese furnace. I don't know what to think of Fogatti. They 496 00:31:11,950 --> 00:31:15,110 kind of got their way into the RV industry. Like, one day they're 497 00:31:15,110 --> 00:31:17,870 not here, the next day they're here. Like they've been here forever. 498 00:31:18,910 --> 00:31:21,750 And that's, you know, marketing. They had a nice strategy, 499 00:31:21,750 --> 00:31:24,430 got in, got in with distributors rather than just going 500 00:31:24,430 --> 00:31:28,130 solo selling on the Internet. Although they do just sell on the 501 00:31:28,130 --> 00:31:31,610 Internet and their furnaces. I'm not going to get into their water 502 00:31:31,610 --> 00:31:34,650 heaters or air conditioners. I'm definitely going to talk about 503 00:31:34,650 --> 00:31:38,010 the furnaces. The water heaters I actually sell don't have 504 00:31:38,010 --> 00:31:41,250 a big problem with those. Air conditioners I wouldn't trust because 505 00:31:42,289 --> 00:31:45,730 there are a lot more money. And I just, there's so many air conditioners 506 00:31:45,730 --> 00:31:48,770 on the market and there are so many good ones. Why take a chance? 507 00:31:49,490 --> 00:31:52,490 And same goes with this furnace now, the Fogati furnace. 508 00:31:52,490 --> 00:31:56,500 I bought one after a trade show late, earlier this year. And 509 00:31:56,500 --> 00:31:59,820 it certainly wasn't from stopping at the Fogotti booth and 510 00:31:59,820 --> 00:32:04,180 talking to them. That was an experience like, man, like a swap 511 00:32:04,180 --> 00:32:07,740 meet experience. You buy now, you buy now. That's all they're trying 512 00:32:07,740 --> 00:32:11,180 to do is sell furnaces or product. They could care less what 513 00:32:11,180 --> 00:32:15,860 your questions are. It was amazing. It was absolutely amazing. 514 00:32:16,260 --> 00:32:19,980 The only reason why Fogadi got my attention of the furnace is because 515 00:32:19,980 --> 00:32:25,640 I went to a seminar and they had a rep, a rep group, a manufacturer's 516 00:32:25,640 --> 00:32:28,680 rep group, talking about the furnaces and some of the cool things 517 00:32:28,680 --> 00:32:33,000 about the features. And I bought one. A medium size is what 518 00:32:33,000 --> 00:32:39,280 they call it 30,000 or 35,000 BTU. And the thing is awesome. It 519 00:32:39,280 --> 00:32:44,080 really does everything they say it's going to do. It's quieter, 520 00:32:44,560 --> 00:32:50,440 you know, it's variable speed, blower, everything's quiet. The only 521 00:32:50,440 --> 00:32:54,240 noise, it even has sleep mode. So it's quieter in sleep mode. But 522 00:32:54,240 --> 00:32:57,280 the only noise you hear is when it lights up. You know, you 523 00:32:57,280 --> 00:33:02,320 get the. The fan goes on full speed, then you hear the. And then 524 00:33:02,320 --> 00:33:05,720 it kind of goes back down into quiet mode so you can sleep. And 525 00:33:05,720 --> 00:33:10,840 sleep mode is so you don't get woken up by your appliance, but if 526 00:33:10,840 --> 00:33:14,410 it doesn't wake you up, then you're probably cool. But me, that 527 00:33:14,410 --> 00:33:17,330 would wake me up. But that's all right. I can deal with it, you 528 00:33:17,330 --> 00:33:21,850 know. So I bought one and tested it, put it on the bench, tested 529 00:33:21,850 --> 00:33:24,410 it for about a week. Different things, more. I thought about it, 530 00:33:24,410 --> 00:33:27,930 tried this, tried that, and then I. Alright, so let's see. Will 531 00:33:27,930 --> 00:33:33,650 this fit in my rv? And start looking at it now. And I call Fogati. 532 00:33:33,650 --> 00:33:36,730 Oh yeah, it's going to fit. Oh, it's going to fit. Well, do you 533 00:33:36,730 --> 00:33:41,260 have a door kit for it? And their idea of a door kit is a piece 534 00:33:41,260 --> 00:33:43,460 of metal. Stamps look like door. Nothing wrong with it. You 535 00:33:43,460 --> 00:33:47,100 know, it looks okay, but it's not really a door kit. It's just 536 00:33:47,100 --> 00:33:50,620 a door, a piece of metal. There's no frame for it, there's 537 00:33:50,620 --> 00:33:55,700 no. Nothing. I thought was really interesting because all the 538 00:33:55,700 --> 00:33:58,940 other brands, Suburban, Dometic, you know, even Hydroflame, 539 00:33:58,940 --> 00:34:03,940 Atwood back in the day, they'll have door kits. They're designed 540 00:34:04,020 --> 00:34:08,430 to have a door on them. And it's very specific. And I talked 541 00:34:08,430 --> 00:34:12,030 to the manufacturer's rep firm. They weren't 100%. They tried 542 00:34:12,030 --> 00:34:15,910 to help, couldn't help much. Fogotti was no help whatsoever. The 543 00:34:15,910 --> 00:34:18,790 fact I could talk to someone was surprising, but they really couldn't 544 00:34:18,790 --> 00:34:21,670 understand a whole lot of what I was saying. And I don't think they 545 00:34:21,670 --> 00:34:24,750 really cared what I was saying. And if there's somebody that 546 00:34:24,750 --> 00:34:27,510 works at Fogati or Fogatti hears this, hey, reach out to me, 547 00:34:27,510 --> 00:34:31,230 man, I'd love to hear it. I'll correct all of this if you reach 548 00:34:31,230 --> 00:34:34,790 out to me. But there is no way that furnace would work in my RV 549 00:34:34,790 --> 00:34:38,500 with a dometic furnace. No matter what furnace I had from dometic, 550 00:34:39,529 --> 00:34:42,489 you'd have to cut a hole in the RV to make it bigger to put this 551 00:34:42,489 --> 00:34:47,009 thing in there. And what sucks about that is you cut the hole for 552 00:34:47,009 --> 00:34:50,929 this furnace. Now you're obligated for a Fogati furnace for 553 00:34:50,929 --> 00:34:54,688 the rest of your life. You know, once you make the hole inside 554 00:34:54,688 --> 00:34:57,969 the RV bigger, and you're gonna have to frame it in. So if 555 00:34:57,969 --> 00:35:01,929 you buy one, really think about it. Are you gonna trust this 556 00:35:01,929 --> 00:35:05,649 furnace forever? And are you gonna be able to frame it in so it's 557 00:35:05,649 --> 00:35:08,649 solid on the side? They're not just fiberglass, you know, bouncing 558 00:35:08,649 --> 00:35:12,870 down the road. Then from what I can see on the door, it's a piece 559 00:35:12,870 --> 00:35:17,630 of metal. You put some caulking on the back of it and put 560 00:35:17,630 --> 00:35:21,070 it against the side of the RV and put four screws in. And that's 561 00:35:21,070 --> 00:35:23,950 why it has to be framed out on the inside, is for those screws need 562 00:35:23,950 --> 00:35:27,110 to attach to something. If they just go into the fiberglass, 563 00:35:27,110 --> 00:35:30,550 they'll just fall out. And then think about that. You just glued 564 00:35:30,550 --> 00:35:33,590 the door to the side of your rv. What's the point in the screws 565 00:35:35,760 --> 00:35:38,760 right now? Maybe I'm missing something there. But, you know, you. 566 00:35:38,760 --> 00:35:41,440 To pull that door off, you have to break that seal every time. 567 00:35:41,440 --> 00:35:44,880 Is that door going to get ruined? You're going to find out. 568 00:35:45,360 --> 00:35:48,200 So think long and hard about it. And like I said, if somebody 569 00:35:48,200 --> 00:35:51,480 at Fogadi can correct me on this or somebody knows these Fogotti 570 00:35:51,480 --> 00:35:54,400 furnaces inside and out and correct me, I'd love to hear it. 571 00:35:55,120 --> 00:35:58,360 But I do know you have to cut the side of the RV open. And they 572 00:35:58,360 --> 00:36:00,560 told me that, oh, no, you got to make the hole bigger no matter 573 00:36:00,560 --> 00:36:05,520 what. And I took the furnace home. I had a door kit from Dometic. 574 00:36:05,520 --> 00:36:09,400 I had a couple different kits, older ones, newer ones. You know, 575 00:36:09,400 --> 00:36:12,280 I'm gonna make this work. And no way. There's no way I'm making 576 00:36:12,280 --> 00:36:17,359 cutting the whole side of my RV bigger. No way. And I didn't. 577 00:36:17,680 --> 00:36:20,000 So that's what I'm talking about. I was a little annoyed because, 578 00:36:20,800 --> 00:36:24,400 you know, you can do that very easily make the hole bigger, like 579 00:36:24,400 --> 00:36:27,970 whoop dee doo. But, man, once you do it, you're committed. You're 580 00:36:27,970 --> 00:36:31,330 committed to that for life. All right, so it's up to you. You 581 00:36:31,330 --> 00:36:35,410 check out Fogadi, you go to their website, and you can determine 582 00:36:35,410 --> 00:36:38,330 whether you want one or not. You'll find all their dimensions 583 00:36:38,330 --> 00:36:41,290 eventually, and you have to really think about it long and hard 584 00:36:41,290 --> 00:36:45,450 before you ever do such a thing. Now, let's get to smart tips 585 00:36:45,530 --> 00:36:48,930 and talk about familiarizing yourself with your tools. Now, that's 586 00:36:48,930 --> 00:36:52,570 very timely. Right after we're talking about cutting a hole in the 587 00:36:52,570 --> 00:36:54,890 side of your rv. Now you're going to feel familiarize yourself 588 00:36:54,890 --> 00:36:59,210 with your tools. Right? Okay. Well, I taught my. One of my recent 589 00:36:59,290 --> 00:37:02,290 episodes, I think it was the last one, talked about, you know, 590 00:37:02,290 --> 00:37:04,370 buying the boat and the trailer and learning so much from 591 00:37:04,370 --> 00:37:07,410 that experience. And the person who sold me the boat didn't 592 00:37:07,410 --> 00:37:11,090 have a clue about tools yet. He had all these tools, you know. 593 00:37:11,090 --> 00:37:14,410 And I said, then familiarize yourself with your tools. And I'm 594 00:37:14,410 --> 00:37:17,050 going to say it again and I want to emphasize it, you know, I 595 00:37:17,050 --> 00:37:19,810 don't know of any training courses where you can go learn how 596 00:37:19,810 --> 00:37:23,860 to use tools, but you can do it at home. Learn what you have. 597 00:37:24,100 --> 00:37:27,540 Look at your tools in your toolbox. I know from time to time 598 00:37:27,540 --> 00:37:29,780 I'll go through my toolbox because there are things in there 599 00:37:29,780 --> 00:37:33,580 that maybe I thought I needed that now. I don't change vehicles. 600 00:37:33,580 --> 00:37:37,019 Something else changed or there's tools that I don't have in 601 00:37:37,019 --> 00:37:40,300 there that now I know I should have. So I kind of go through there 602 00:37:40,300 --> 00:37:43,460 and it's a reminder too, like, oh, I didn't realize I had that. 603 00:37:43,460 --> 00:37:47,340 I forgot I put that in there because, you know, if tools like 604 00:37:47,340 --> 00:37:50,500 for me, I have tools specifically for my truck and trailer 605 00:37:51,510 --> 00:37:54,710 and sometimes I forget what I have. And so that's why going through 606 00:37:54,710 --> 00:37:57,150 is nice. Because I have tools in my garage that I do everything 607 00:37:57,150 --> 00:38:00,590 else with. So it's not like I'm borrowing, you know, going back 608 00:38:00,590 --> 00:38:03,910 and forth. That's they're designated for the RV and the truck 609 00:38:03,990 --> 00:38:09,310 basically, but learning how to use them, what you have, you know, 610 00:38:09,310 --> 00:38:14,270 will this work? Is this really going to be my problem solver? You 611 00:38:14,270 --> 00:38:18,060 know, do I have a half inch breaker bar? What is it? Do I have 612 00:38:18,060 --> 00:38:21,140 a half inch ratchet? What is that? Why would I need a half inch? 613 00:38:21,140 --> 00:38:25,500 Well, what is a ratchet? You know, learn these things. I know 614 00:38:25,500 --> 00:38:30,100 it sounds crazy simple, right? But it's important. So when you're 615 00:38:30,100 --> 00:38:32,620 out on the road, you're not fumbling with that kind of stuff. 616 00:38:32,620 --> 00:38:35,780 When you have a problem you're dealing with, you know, it can be 617 00:38:35,780 --> 00:38:38,940 anything. I mean, you know, it could be a water leak, could be a 618 00:38:38,940 --> 00:38:42,060 blowout. You know, you're in an RV park, but you're fumbling with 619 00:38:42,060 --> 00:38:44,900 tools, trying to figure out, how do I do this? You have a multimeter. 620 00:38:44,900 --> 00:38:48,740 You have no idea how it even works. That's why learning this stuff 621 00:38:48,740 --> 00:38:53,220 beforehand can be such a valuable tool. No pun intended there. 622 00:38:53,700 --> 00:38:57,260 Alright guys, so that's just a really smart, quick, smart tip for 623 00:38:57,260 --> 00:39:01,100 you. And now a final call to action here. There's always a call 624 00:39:01,100 --> 00:39:04,020 to action. I'm not even supposed to say that word. Call to 625 00:39:04,020 --> 00:39:08,420 action. Wow. It's just a reminder. Share this podcast with 626 00:39:08,420 --> 00:39:11,420 your family, your friends. And I've asked you before, and you guys 627 00:39:11,420 --> 00:39:14,500 do a great job. You know, I see our subscribers, new listeners. 628 00:39:15,150 --> 00:39:18,070 We're growing and we're growing, and we like that. It helps 629 00:39:18,070 --> 00:39:22,430 us, makes us want to do this show even more. Although I love doing 630 00:39:22,430 --> 00:39:26,190 the podcast, so I don't see that ever being an issue. But we've 631 00:39:26,190 --> 00:39:30,110 come to the end here. We've run out of time, so I've got to go. 632 00:39:30,910 --> 00:39:33,710 So that's going to be it for today's episode. And I know you're. 633 00:39:33,710 --> 00:39:38,270 You're deeply saddened by that, right? All right, everybody. 634 00:39:38,430 --> 00:39:42,000 So this is a Smart rver podcast. Thanks for listening. I'm 635 00:39:42,000 --> 00:39:44,920 Eric Stark, and if you'd rather be camping than sitting in 636 00:39:44,920 --> 00:39:48,920 a repair shop, you're in the right place. Until next time, take 637 00:39:48,920 --> 00:39:51,640 care of the little things and enjoy the trip.